CCPTP - LUCITE ACRYLIC LACQUER, 404L

Product Identification

Product ID:LUCITE ACRYLIC LACQUER, 404L
MSDS Date:01/01/1993
FSC:8010
NIIN:00N073824
MSDS Number: CCPTP

Responsible Party
E I DUPONT DE NEMOURS & CO
1007 MARKET ST
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515

Cage: 0ERJ7

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

NONE @ 20C

CAS: 9011-14-7

RTECS: TR0400000

OSHA PEL N/K

ACGIH TLV: N/K


8

CAS: 123-86-4

RTECS: AF7350000

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM; 200 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


COPPER, (PHTHALOCYANINATO(2-))-; (PHTHALOCYANINE BLUE

CAS: 147-14-8

RTECS: GL8510000

OSHA PEL N/K

ACGIH TLV: N/K


ACETIC ACID, PENTYL ESTER; (PRIMARY AMYLACETATE) (CERCLA)

CAS: 628-63-7

RTECS: AJ1925000

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


36.7 @ 20C

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 30%

OSHA PEL 200 PPM

ACGIH TLV: 50 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


25 @ 20C

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 47%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM; 150 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


HEARTBEATS IN ANIMALS & OCCAS PALPITATIONS IN

RTECS: 9999999ZZ


EXHIBITED HIGH FREQUENCY HEARING DEFICITS.

RTECS: 9999999ZZ


CAUSED EMBRYOTOXIC EFTS IN LAB ANIMALS. RECURRENT

RTECS: 9999999ZZ


ABSORBED THROUGH THE SKIN IN HARMFUL AMOUNTS.

RTECS: 9999999ZZ


SPRAY OPERATIONS ARE TYPICAL OR PROPER RESP FIT

RTECS: 9999999ZZ


SUPPLIED-AIR RESP (TC-19C). IN ALL CASES, FOLLOW

RTECS: 9999999ZZ


ANYONE W/OUT PROTECTION IN PAINTING AREA.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TOLUENE APPEARS ON THE NAVY LIST OF
OCCUP CHEM REPRO HAZS. SEEK CONSULTATION FROM APPROP HLTH
PROFESSIONALS CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG & EXPOS
INFO . INGEST:GI DISTRESS. INHAL: MAY CAUSE NOSE & THROAT IRRIT.
RPTD & PRLNGD OVEREXP TO SOLVS MAY LEAD TO PERM BRAIN & NERVS SYS
DMG. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: EYE WATERING, HDCHS, NAUS, DIZZ &
LOSS OF COORDINATION ARE SIGNS THAT SOLV LEVELS ARE TOO HIGH.
EYES:MAY CAUSE IRRIT/BURNING. SKIN:RPTD/ PRLNGD LIQ CNTCT MAY CAUSE
IRRIT W/DISCOMFORT & DERM. BUTYL ACETATE: MAY CAUSE ABNORMAL LIVER
FUNC. TESTS FOR EMBRYOTOXIC ACTIVITY IN ANIMALS HAS BEEN
INCONCLUSIVE. (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: IN UNLIKELY EVENT OF INGESTION, CALL MD IMMEDIATELY
AND HAVE NAMES OF INGREDIENTS AVAILABLE. INHAL: IF AFFECTED BY
INHALATION OF VAPOR/SPRAY MIST, REMOVE TO FRESH AIR. IF BREATHING
DIFFICULTY PERSISTS OR OCCURS LATER, CONSULT MD. EYES: IMMEDIATELY
FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES; CALL MD. SKIN:
WASH WITH SOAP AND WATER. IF IRRITATION OCCURS, CONTACT MD.

Fire Fighting

Flash Point Method:CC
Flash Point:<73F,<23C
Lower Limits:0.2%
Upper Limits:36.5%
Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILD UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE THE FLASH POINT, EMITS
FLAM VAPS WHICH, WHEN MIXED W/AIR, CAN BURN OR BE EXPLOSIVE. FINE
MISTS/SPRAYS MAY BE FLAM AT TEMPS BELOW FLASH POINT.

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
PREVENT SKIN CONTACT AND BREATHING OF VAPOR. WEAR NIOSH APPROVED,
PROPERLY FITTED VAPOR/PARTICULATE RESPIRATOR (TC-23C). CONFINE AND
REMOVE WITH INERT ABSOR BENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS AND FLAME. CLOSE CONTAINER AFTER EACH USE. GROUND
CONTAINERS WHEN POURING.
Other Precautions:WASH THOROUGHLY AFTER HANDLING AND BEFORE EATING OR
SMOKING. DO NOT STORE ABOVE 120F. DO NOT SAND, FLAME CUT, BRAZE OR
WELD DRY COATING WITHOUT A NIOSH APPROVED RESPIRATOR OR APPROPRIATE
VENTILATION.

Exposure Controls

Respiratory Protection:DO NOT BREATHE VAPS/MISTS. WEAR PROPERLY FITTED
VAP/PARTICULATE RESP APPRVD BY NIOSH (TC-23C) FOR USE W/PAINTS
DURING APPLICATN & UNTIL ALL VAPS & SPRAY MISTS ARE EXHAUSTED. IN
CONFINED SPACES/IN SITU ATIONS WHERE CONTINUOUS (ING 11)
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
COVERALLS ARE RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: HAS BEEN TOX TO FETUS IN LAB ANIMALS AT DOSES TOX TO
MOTHER. PRIMARY AMYL ACETATE: RECURRENT OVEREXP MAY RSLT IN LIVER &
KIDNEY INJURY. MATL IS IRRIT TO MUC MEMBS & UPPER RESP TRACT.
TOLUENE: RECURRENT OVEREXP MAY RSLT IN LIVER & KIDNEY INJURY. HIGH
AIRBORNE LEVELS HAVE PRDCED IRREGULAR (ING 7)

Chemical Properties

Boiling Pt:B.P. Text:>129F,>54C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.91-1.31
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:57-84

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORSEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SMOKE.

Disposal

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED
CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.