CCPTP - LUCITE ACRYLIC LACQUER, 404L
- MSDS: CCPTP
- Manufacturer: E I DUPONT DE NEMOURS AND CO
- Product Name: LUCITE ACRYLIC LACQUER, 404L
- National Stock Number: 8010-00N073824
Product Identification
Product ID:LUCITE ACRYLIC LACQUER, 404L
MSDS Date:01/01/1993
FSC:8010
NIIN:00N073824
MSDS Number: CCPTP
Responsible Party
WILMINGTON, DE 19898
US
Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)
Info Phone: 800-441-7515
Cage: 0ERJ7
Contractor
Telephone: 800-441-7515;800-441-9442
Cage: 18873
Ingredients
NONE @ 20C
CAS: 9011-14-7
RTECS: TR0400000
OSHA PEL N/K
ACGIH TLV: N/K
8
CAS: 123-86-4
RTECS: AF7350000
OSHA PEL 150 PPM
ACGIH TLV: 150 PPM; 200 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
COPPER, (PHTHALOCYANINATO(2-))-; (PHTHALOCYANINE BLUE
CAS: 147-14-8
RTECS: GL8510000
OSHA PEL N/K
ACGIH TLV: N/K
ACETIC ACID, PENTYL ESTER; (PRIMARY AMYLACETATE) (CERCLA)
CAS: 628-63-7
RTECS: AJ1925000
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
36.7 @ 20C
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 30%
OSHA PEL 200 PPM
ACGIH TLV: 50 PPM, S
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
25 @ 20C
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 47%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM; 150 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
HEARTBEATS IN ANIMALS & OCCAS PALPITATIONS IN
RTECS: 9999999ZZ
EXHIBITED HIGH FREQUENCY HEARING DEFICITS.
RTECS: 9999999ZZ
CAUSED EMBRYOTOXIC EFTS IN LAB ANIMALS. RECURRENT
RTECS: 9999999ZZ
ABSORBED THROUGH THE SKIN IN HARMFUL AMOUNTS.
RTECS: 9999999ZZ
SPRAY OPERATIONS ARE TYPICAL OR PROPER RESP FIT
RTECS: 9999999ZZ
SUPPLIED-AIR RESP (TC-19C). IN ALL CASES, FOLLOW
RTECS: 9999999ZZ
ANYONE W/OUT PROTECTION IN PAINTING AREA.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TOLUENE APPEARS ON THE NAVY LIST OF
OCCUP CHEM REPRO HAZS. SEEK CONSULTATION FROM APPROP HLTH
PROFESSIONALS CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG & EXPOS
INFO . INGEST:GI DISTRESS. INHAL: MAY CAUSE NOSE & THROAT IRRIT.
RPTD & PRLNGD OVEREXP TO SOLVS MAY LEAD TO PERM BRAIN & NERVS SYS
DMG. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: EYE WATERING, HDCHS, NAUS, DIZZ &
LOSS OF COORDINATION ARE SIGNS THAT SOLV LEVELS ARE TOO HIGH.
EYES:MAY CAUSE IRRIT/BURNING. SKIN:RPTD/ PRLNGD LIQ CNTCT MAY CAUSE
IRRIT W/DISCOMFORT & DERM. BUTYL ACETATE: MAY CAUSE ABNORMAL LIVER
FUNC. TESTS FOR EMBRYOTOXIC ACTIVITY IN ANIMALS HAS BEEN
INCONCLUSIVE. (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INGEST: IN UNLIKELY EVENT OF INGESTION, CALL MD IMMEDIATELY
AND HAVE NAMES OF INGREDIENTS AVAILABLE. INHAL: IF AFFECTED BY
INHALATION OF VAPOR/SPRAY MIST, REMOVE TO FRESH AIR. IF BREATHING
DIFFICULTY PERSISTS OR OCCURS LATER, CONSULT MD. EYES: IMMEDIATELY
FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES; CALL MD. SKIN:
WASH WITH SOAP AND WATER. IF IRRITATION OCCURS, CONTACT MD.
Fire Fighting
Flash Point Method:CC
Flash Point:<73F,<23C
Lower Limits:0.2%
Upper Limits:36.5%
Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILD UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE THE FLASH POINT, EMITS
FLAM VAPS WHICH, WHEN MIXED W/AIR, CAN BURN OR BE EXPLOSIVE. FINE
MISTS/SPRAYS MAY BE FLAM AT TEMPS BELOW FLASH POINT.
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
PREVENT SKIN CONTACT AND BREATHING OF VAPOR. WEAR NIOSH APPROVED,
PROPERLY FITTED VAPOR/PARTICULATE RESPIRATOR (TC-23C). CONFINE AND
REMOVE WITH INERT ABSOR BENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS AND FLAME. CLOSE CONTAINER AFTER EACH USE. GROUND
CONTAINERS WHEN POURING.
Other Precautions:WASH THOROUGHLY AFTER HANDLING AND BEFORE EATING OR
SMOKING. DO NOT STORE ABOVE 120F. DO NOT SAND, FLAME CUT, BRAZE OR
WELD DRY COATING WITHOUT A NIOSH APPROVED RESPIRATOR OR APPROPRIATE
VENTILATION.
Exposure Controls
Respiratory Protection:DO NOT BREATHE VAPS/MISTS. WEAR PROPERLY FITTED
VAP/PARTICULATE RESP APPRVD BY NIOSH (TC-23C) FOR USE W/PAINTS
DURING APPLICATN & UNTIL ALL VAPS & SPRAY MISTS ARE EXHAUSTED. IN
CONFINED SPACES/IN SITU ATIONS WHERE CONTINUOUS (ING 11)
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
COVERALLS ARE RECOMMENDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: HAS BEEN TOX TO FETUS IN LAB ANIMALS AT DOSES TOX TO
MOTHER. PRIMARY AMYL ACETATE: RECURRENT OVEREXP MAY RSLT IN LIVER &
KIDNEY INJURY. MATL IS IRRIT TO MUC MEMBS & UPPER RESP TRACT.
TOLUENE: RECURRENT OVEREXP MAY RSLT IN LIVER & KIDNEY INJURY. HIGH
AIRBORNE LEVELS HAVE PRDCED IRREGULAR (ING 7)
Chemical Properties
Boiling Pt:B.P. Text:>129F,>54C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.91-1.31
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:57-84
Stability
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORSEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
SMOKE.
Disposal
Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED
CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.